GKPX20
Target Product COCOA BEANS
Certification CE, ISO9001, ISO22000
Material Chrome Surface , Carbon Steel
Batch Capacity. 20 KG
Roasting Duration. 12- 25 min (average)
Hour Capacity. 40 kg/h
Roasting Type. DIRECT FIRE
Heating System. POLIDORO – ITALIAN BURNER
ROASTING SKILLS.
Fuel Type LPG/NG
Control PID Bean Temperature Control Flame Management
Air Flow Control
Gas Control
Drum Speed Control Emergency
USB Data Logging
Voltage 380V 3Phase
Motor1 5 units
(Drum, Upper Fan, Cooling Fan, Cooling Mixer, Chaff Collector)
Frequency 50 / 60 Hz
Electric Consumption 3,52 kW
TECHNICAL
Roasting Energy 32,5 kW
Gas Consumption 1,9 m3/h (LPG) 3,5 m3/h (NG)
Exhaust Outlet
200 MM
USB LOG
MODBUS
K TYPE THERMOCOUPLE (DRUM TEMP – EXHAUST TEMP)
• Control
o Electrical Control Panel
▪ Manual Operations
▪ Drum button
▪ Cooling Fan button
▪ Cooling Mixer button
▪ Light button
▪ Adjustable Digital Temperature Control
▪ Bean Temperature
▪ Adjustable Digital Display Control
▪ Exhaust Temperature
▪ Drum Speed Control ▪ Flame Control
o Air Flow Control Manual o Gas Control System
▪ Polidoro Heating System
-
▪ Homogeneous heating flame through the drum and uniformly distrubuted surface heat
-
▪ The safety for fireback
-
▪ The flame is easily arranged according to requested heat which
guides the low fuel consumption whilst processing the balanced roast.
-
External Chaff Collector
-
Roasting Monitoring (Manual)
o sampling spoon o sight glass
• Drum Window • Cooling
o Cooling fan , Mixer , Cover
• Stairs for loading
POLIDORO HEATING SYSTEM
The main operating characteristics guarantee:
-
low emissions in compliance with the current European regulations
-
low noise levels, compliant to the strictest European standards
-
efficiency according to 3-star standard for traditional boilers, both open-chamber and
sealed chamber
-
efficiency according to 4-star standard for condensing boilers with recuperator
-
operation without the need to calibrate the gas valves where smart combustion
systems are involved
-
function on gases of the first, second and third families by changing the injectors,
without any air regulation system
This specific construction system allows for the creation of burners:
-
easily adaptable to any heat exchanger
-
with different widths, varying the number of elements from a minimum of 5 to a
maximum of 20
-
with different depths, using burner bodies L=157mm or L=140mm
-
The NP burner is compatible with:
-
electronic ignition systems, either mono or multiple electrode, that may be positioned
either on the plate or on the spacer
-
ignition system with pilot, that may be positioned either on the plate or on the spacer
-
GRS - Roasting Profile System (Beijer)
▪ Profile Operations
▪ Prepare & Record Receipts
▪ Add all data to determined variables on Receipts
▪ Flame Level
▪ Setting Degree / Drum Temperature ▪ First and Second Cracks
▪ Roasting Duration and more.
▪ Monitor Graph of the Roasting Process
▪ Warning system for steps of roasting (Receipt Roasting) – to
guide operator
▪ Motor Fault Warning system
-
▪ Gas Fault Warning system
-
▪ Operate the machine on Touch Screen Panel
-
▪ The system can be controlled via PC/Laptop when the Ethernet
cable is adjusted.
-
▪ Receive data and images of manual and profile roasting
-
▪ Pneumatic Operations
EXW PRICE
Price standard 20,500.0 EUR
Price Automation 27,200.0 EUR